RTU Research Information System
Latviešu English

Publikācija: 3D Camera Calibration for Motion Tracking in Recurrent Athletic Environment

Publication Type Conference paper
Funding for basic activity Unknown
Defending: ,
Publication language English (en)
Title in original language 3D Camera Calibration for Motion Tracking in Recurrent Athletic Environment
Field of research 2. Engineering and technology
Sub-field of research 2.6 Medical engineering
Authors Veronika Fedotova
Viktors Piļipivs
Keywords motion capture, computer modelling, reconstruction of coordinates
Abstract 3D model of the ramp was created from projections captured on the videos. Virtual calibration markers with known coordinates of the centres were spread over the model covering the area of interest. The 3D DLT calibration procedure for the cameras (Abdel-Aziz and Karara, 1971) in Simi software can be performed by substituting the calibration videos with corresponding projections of the model and mapping the virtual markers. The projections shall be overlaid the respective movement videos from the cameras in order to obtain the precise alignment of the camera views. Comparison of the calibration results using the standard calibration procedure and the innovative method had shown that the difference in coordinate estimation with the two methods is within a measurement error.
Reference Fedotova, V., Piļipivs, V. 3D Camera Calibration for Motion Tracking in Recurrent Athletic Environment. In: Abstracts of the 5th Baltic Sport Science Conference “Current Issues and New Ideas in Sport Science”, Lithuania, Kaunas, 18-19 April, 2012. Kaunas: Lietuvos kūno kultūros akademija, 2012, pp.64-64. ISBN 978-609-8040-70-8.
Full-text