Industrial Research of Condensing Unit for Natural Gas Boiler House
2012
Jelena Ziemele, Dagnija Blumberga, Normunds Talcis, Ilze Laicāne

In the course of work industrial research was carried out at the boiler plant A/S “Imanta” where a 10MW passive condensing economizer working on natural gas was installed after the 116MW water boiler. The work describes the design of the condensing economizer and wiring diagram. During the industrial experiment, the following measurements were made: the temperature of water before and after the economizer; the ambient temperature; the quantity of water passing through the economizer; heat, produced by the economizer and water boilers. The work summarizes the data from 2010-2011.


Keywords
condensing economizer, energy efficient, latent heat, flue gas
DOI
10.2478/v10145-012-0023-9

Ziemele, J., Blumberga, D., Talcis, N., Laicāne, I. Industrial Research of Condensing Unit for Natural Gas Boiler House. Environmental and Climate Technologies. Vol.10, 2012, pp.34-38. ISSN 1691-5208. e-ISSN 2255-8845. Available from: doi:10.2478/v10145-012-0023-9