Impact of Component Losses on the Efficiency of the LC-Filter Based Dual Active Bridge for the Isolation Stage of Power Electronic Transformer
8th International Conference-Workshop on Compatibility and Power Electronics (CPE 2013)
2013
viktor Beldjajev,
Tonu Lehtla,
Jānis Zaķis
This paper presents a steady state analysis of the
commutating LC-filter based dual active bridge (DAB)
considering the conduction losses in the components. The aim is
to use this converter in power electronic transformer (PET). The
LC-filter offers the boost properties with a small component
count and DAB allows effective power flow control and soft
switching capabilities. Such combination allows the voltage on
the transformer terminals to be kept at the desired level to
enable the best performance of the converter. In order to
facilitate the impact of the losses on the power characteristics
and efficiency the mathematical loss models are derived and
experimental results are presented.
Keywords
dual active bridge converter, commutating LC-filter, power electronic transformer, conduction losses
DOI
10.1109/CPE.2013.6601142
Hyperlink
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6601142
Beldjajev, v., Lehtla, T., Zaķis, J. Impact of Component Losses on the Efficiency of the LC-Filter Based Dual Active Bridge for the Isolation Stage of Power Electronic Transformer . In: 8th International Conference-Workshop on Compatibility and Power Electronics (CPE 2013), Slovenia, Ljubljana, 5-7 June, 2013. Piscataway: IEEE, 2013, pp.132-137. ISBN 978-1-4673-4911-6. ISSN 2166-9538. Available from: doi:10.1109/CPE.2013.6601142
Publication language
English (en)