Continuous Monitoring of Parasitic Elements in Boost Converter Circuit
2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia 2021): Proceedings 2021
Aleksandrs Suzdaļenko, Viktorija Sribnija, Jānis Zaķis, Khang Van Huynh

The given paper explains the necessity of condition monitoring for DC/DC boost converter circuit. Further, an analytical model of circuit parasitic estimation is presented based on measured quantities in the circuit. The implementation of continuous estimation of circuit parasitic elements is analytically explained and verified by simulations and experimental results. Obtained results are acceptable for condition monitoring.


Keywords
condition monitoring | DC/DC converter | parasitic elements
DOI
10.1109/ECCE-Asia49820.2021.9479093
Hyperlink
https://ieeexplore.ieee.org/document/9479093/

Suzdaļenko, A., Sribnija, V., Zaķis, J., Van Huynh, K. Continuous Monitoring of Parasitic Elements in Boost Converter Circuit. In: 2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia 2021): Proceedings, Singapore, Singapore, 24-27 May, 2021. Piscataway: IEEE, 2021, pp.1829-1832. ISBN 978-1-7281-6345-1. e-ISBN 978-1-7281-6344-4. ISSN 2150-6078. e-ISSN 2150-6086. Available from: doi:10.1109/ECCE-Asia49820.2021.9479093

Publication language
English (en)
The Scientific Library of the Riga Technical University.
E-mail: uzzinas@rtu.lv; Phone: +371 28399196