This database includes series of measurements of the structure's response taken in six-dimensional space using two 6D sensors, coaxially positioned in two different ways on either side of the investigated panel-to-panel connection. Presented data related to ten different states of joints, two load levels, and two type of input signal (short impulse and sweep signal with duration 0.5 seconds with frequency range from 10 Hz to 2000 Hz). In the "Read_me_first.pdf" is described the experiment, the format of .csv files names and files' structure. Used materials, methods and results for the case of static load equal to 151.8 kg with sweep-type input signal, and T2 scheme of sensors placement is described in Kurtenoks, V.; Kurajevs, A.; Buka-Vaivade, K.; Serdjuks, D.; Lapkovskis, V.; Mironovs, V.; Podkoritovs, A.; Vilnitis, M. The Quality Assessment of Timber Structural Joints Using the Coaxial Correlation Method. Buildings 2023, 13, 1929. https://doi.org/10.3390/buildings13081929