EEG Data Acquisition System Based on Asynchronous Sigma-Delta Modulator
Proceedings of the 13th Biennial Baltic Electronics Conference (BEC 2012) 2012
Kaspars Ozols, Modris Greitāns, Rolands Šāvelis

This paper describes a multichannel mobile EEG data acquisition system that consists of on-head sensors with built in electroencephalogram (EEG) signal amplifier, asynchronous sigma-delta modulator (ASDM) for analog to digital conversion and 434MHz On-Off keying (OOK) wireless data transmitter. A prototype circuit has been designed and fabricated in a 11×16mm cylinder package. After receiving the signal, appropriate processing is applied in order to reconstruct the brain wave signals.


Atslēgas vārdi
Asynchronous sigma delta modulator, signal reconstruction
DOI
10.1109/BEC.2012.6376847
Hipersaite
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6376847

Ozols, K., Greitāns, M., Šāvelis, R. EEG Data Acquisition System Based on Asynchronous Sigma-Delta Modulator. No: Proceedings of the 13th Biennial Baltic Electronics Conference (BEC 2012), Igaunija, Tallinn, 3.-5. oktobris, 2012. Piscataway: IEEE, 2012, 183.-186.lpp. ISBN 978-1-4673-2775-6. ISSN 1736-3705. Pieejams: doi:10.1109/BEC.2012.6376847