Energy and Exergy Analysis of Vertical Closed-Loop and Open Loop Geothermal Heat Pumps
International Symposium, Dedicated to the 150 Anniversary of the Faculty of Transport and Mechanical Engineering: Scientific Program and Book af Abstracts 2014
Pēteris Stanka, Dmitrijs Rusovs, Sigurds Jaundālders

The paper describes experimental measurement of operation two existing heat pumps Junkers TE 60 and Dimplex SI 8TU. The heat pump Junkers TE 60 use open-loop represented by ground water borehole, which flow directly through evaporator. For the second heat pump Dimplex SI 8TU evaporator was warmed up by water brine solution flow in closed-loop system from three vertical boreholes with 60 m depth each. The heating systems for both pumps were done by radiators in first case and by warm floor in the second one. Energy and exergy balances were carried out from characteristic point of cycles.


Atslēgas vārdi
Geothermal heat pump, energy and exergy balance

Stanka, P., Rusovs, D., Jaundālders, S. Energy and Exergy Analysis of Vertical Closed-Loop and Open Loop Geothermal Heat Pumps. No: International Symposium, Dedicated to the 150 Anniversary of the Faculty of Transport and Mechanical Engineering: Scientific Program and Book af Abstracts, Latvija, Riga, 16.-20. oktobris, 2014. Riga: RTU, 2014, 42.-43.lpp. ISBN 978-9984-9990-9-8.