            Ten different modulation methods of the isolated
quasi Z-source inverter based DC-DC converter were tested to
find out radiated emission levels. EMC measurements were
performed on a low power 250 W prototype. A radiated emission
test was carried out in a GTEM cell (gigahertz transverse
electromagnetic cell) according to the EMC standard IEC 61000-
4-20. To obtain a complete overview of the emissions, both C and
D bands were included in a single test at the start and stop
frequencies 30 MHz and 1 GHz, respectively. Measuring
bandwidth of 120 kHz with a 6 dB EMI filter was used.
            
            
            
                Atslēgas vārdi
                Quasi Z source, DC-DC converters, isolated boost converters, radiated EMI measurement
            
            
                DOI
                10.1109/PowerEng.2015.7266314
            
            
            
            Jalakas, T., Jarkovoi, M., Roasto, I., Zaķis, J., Garganeev, A. Investigation of Radiated Emissions of a Galvanically Isolated qZS DC-DC Converter. No: 2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG): Proceedings, Latvija, Rīga, 11.-13. maijs, 2015. Riga: Riga Technical University, 2015, 176.-181.lpp. ISBN 978-1-4673-7203-9. e-ISBN 978-1-4799-9978-1. e-ISSN 2155-5532. Pieejams: doi:10.1109/PowerEng.2015.7266314
            