Comparison of the Yield from Two Faecal Immunochemical Tests at Identical Cutoff Concentrations - a Randomized Trial in Latvia
European Journal of Gastroenterology and Hepatology 2016
Daiga Šantare, Ilona Kojalo, Inta Liepniece-Karele, Ilze Ķikuste, Ivars Tolmanis, Inese Poļaka, Uldis Vikmanis, Viesturs Boka, Mārcis Leja

Objective We have compared the performance of two faecal immunochemical tests (FIT) in an average-risk population. Materials and methods Altogether, 10 000 individuals aged 50-74 were selected randomly from the population of Latvia in 2011 and assigned randomly either to OC-Sensor or to FOB Gold single-time testing. Positivity of the test, frequency of colonic lesions, number needed to screen (NNscreen) and scope for the detection of an advanced neoplasm (cancer and advanced adenoma) were compared between the tests using the same cutoff concentrations in μg/g faeces. Confidence intervals (CIs) at 95% were calculated. Results Positivity with the cutoff set at 10 μg/g faeces was 12.8% (95% CI: 11.4-14.2) for FOB Gold and 8.3% (95% CI: 7.2-9.4) for OC-Sensor (P<0.001). Positivity was higher in men and the older age groups. Colonoscopy compliance was 55.5%. There was no significant difference between the two tests at comparable cutoff concentrations in μg/g, colonoscopy attendance rate or colonoscopy results. For advanced neoplasm detection, there was no significant difference in number needed to scope and NNscreen at a cutoff of 10 μg/g faeces; however, lower NNscreen was required to detect advanced neoplasms with the FOB Gold test at increased cutoff concentrations. Conclusion Different quantitative FIT systems may report different positivity rate at identical cutoff concentrations, which has to be considered when implementing the use of FIT in national screening programmes.


Atslēgas vārdi
advanced neoplasm; colonoscopy; colorectal cancer screening; cutoff; faecal immunochemical test
DOI
10.1097/MEG.0000000000000650
Hipersaite
https://www.scopus.com/record/display.uri?eid=2-s2.0-84973912662&origin=resultslist&sort=plf-f&src=s&st1=Polaka&st2=&sid=69BD682E573E5D3115BB8E20505BA04E.wsnAw8kcdt7IPYLO0V48gA%3a10&sot=b&sdt=b&sl=19&s=AUTHOR-NAME(Polaka)&relpos=0&citeCnt=0&searchTerm=#corrAuthorFooter

Šantare, D., Kojalo, I., Liepniece-Karele, I., Ķikuste, I., Tolmanis, I., Poļaka, I., Vikmanis, U., Boka, V., Leja, M. Comparison of the Yield from Two Faecal Immunochemical Tests at Identical Cutoff Concentrations - a Randomized Trial in Latvia. European Journal of Gastroenterology and Hepatology, 2016, Vol.28, Iss.8, 904.-910.lpp. ISSN 0954-691X. e-ISSN 1473-5687. Pieejams: doi:10.1097/MEG.0000000000000650

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196