Theoretical and Practical Study of the Effect of  DC Grid Wire Temperature Variation on  Transmission Losses
            
            International Symposium on Fundamentals of Electrical Engineering 2023
            2023
            
        
                Ģirts Staņa,
        
                Viesturs Bražis
        
    
            
            
            The ohmic resistance of DC lines causes losses during power transmission while variations in conductor temperature change the resistance accordingly. Typically, the resistances of specific wires mentioned in technical documentation correspond to some constant reference temperature which is usually 20⁰C. It was therefore decided to analyze the effect of the temperature of overhead catenary wires on the amount of transmission losses and total energy consumption in the case of trolleybus motion by means of simulations and calculations. In the practical part, an experimental study was performed to investigate how the voltage drop on DC lines increases due to temperature increase when an electricity consumer is operated at constant power.
            
            
            
                Atslēgas vārdi
                temperature, transmission losses, transmission  lines, public transportation
            
            
                DOI
                10.1109/ISFEE60884.2023.10637161
            
            
            
            Staņa, Ģ., Bražis, V. Theoretical and Practical Study of the Effect of DC Grid Wire Temperature Variation on Transmission Losses. No: International Symposium on Fundamentals of Electrical Engineering 2023, Rumānija, Bucharest, 16.-18. novembris, 2023. Piscataway: IEEE, 2023, 1.-6.lpp. e-ISBN 979-8-3503-0856-3. e-ISSN 2836-1695. Pieejams: doi:10.1109/ISFEE60884.2023.10637161
            
                Publikācijas valoda
                English (en)