Elements on the Base of Perforated Steel Band for Wall Structures
2004
Viktors Mironovs, Dmitrijs Serdjuks, Videvuds Ārijs Lapsa

It was shown, that profiles on the base of perforated steel bands, which are wastes of stamping production, could be used as a load bearing and reinforcing elements of wall structures. Using of profiles on the base of perforated steel band together with the glued joints enables to improve wall structure. It was stated by the experiment, that gypsum glue has enough shear strength (more than 0,073kg/mm2) to take up dead weight of protective plates of wall structure. It is experimentally established, that micro hardness of anticorrosive zinc coating is 75 MPa. Value of hardness by Brinel is within the limits of 1060-1200 МPа. It is shown, that load bearing capacity of elements with double-T profile from the perforated steel band is 0,4-2,6 кN at flexibility 75-220.


Atslēgas vārdi
perforated steel band, industrial wastes, wall structures

Mironovs, V., Serdjuks, D., Lapsa, V. Elements on the Base of Perforated Steel Band for Wall Structures. Construction Science. Nr.5, 2004, 188.-193.lpp. ISSN 1407-7329.

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196