Battery Monitoring Using High Frequency Impedance Modulation through Series Power Line
38th Annual Conference on IEEE Industrial Electronics Society (IECON 2012): USB Proceedings 2012
Andrejs Stepanovs, Maksims Vorobjovs, Iļja Galkins

The paper deals with a power line interface suitable for implementation in systems composed of series connected energy storage or generation cells, for example, battery cells supercapacitors etc. The interface, which does not use any additional wiring, utilizes amplitude modulation to transmit data in one direction and impedance modulation - to transmit in the opposite. In the paper the features of the proposed interface are described and analyzed. Then a practical example of the proposed interface is given. Possible implementation of the interface for battery monitoring needs is also discussed.


Atslēgas vārdi
Communication, Networking & Broadcasting ; Components, Circuits, Devices & Systems ; Computing & Processing (Hardware/Software) ; Fields, Waves & Electromagnetics ; Geoscience ; Power, Energy, & Industry Applications
DOI
10.1109/IECON.2012.6389553
Hipersaite
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6389553

Stepanovs, A., Vorobjovs, M., Galkins, I. Battery Monitoring Using High Frequency Impedance Modulation through Series Power Line. No: 38th Annual Conference on IEEE Industrial Electronics Society (IECON 2012): USB Proceedings, Kanāda, Montreal, 25.-28. oktobris, 2012. Piscataway: IEEE, 2012, 5148.-5152.lpp. ISBN 978-1-4673-2419-9. e-ISBN 978-1-4673-2420-5. ISSN 1553-572X. Pieejams: doi:10.1109/IECON.2012.6389553

Publikācijas valoda
English (en)
RTU Zinātniskā bibliotēka.
E-pasts: uzzinas@rtu.lv; Tālr: +371 28399196