Zinātniskās darbības atbalsta sistēma
Latviešu English

Publikācija: Economical Aspects of Water-Mist Assisted Air-Cooled Chillers Usage in the Temperate Climate

Publikācijas veids Zinātniskais raksts, kas indeksēts Web of science un/vai Scopus datu bāzē
Pamatdarbībai piesaistītais finansējums Pētniecības projekti
Aizstāvēšana: ,
Publikācijas valoda English (en)
Nosaukums oriģinālvalodā Economical Aspects of Water-Mist Assisted Air-Cooled Chillers Usage in the Temperate Climate
Pētniecības nozare 2. Inženierzinātnes un tehnoloģijas
Pētniecības apakšnozare 2.1. Būvniecības un transporta inženierzinātnes
Autori Artūrs Brahmanis
Anatolijs Borodiņecs
Jeļena Tihana
Jurģis Zemītis
Daria Monastyreva
Atslēgas vārdi energy efficient cooling, adiabatic cooling, mist cooling
Anotācija he prices for energy resources, global trends for greenhouse gases emission limitation makes the application of higher efficient chillers with process air evaporative cooling more common. In order to determine the economical feasibility for choosing the particular type of cooling unit for the specific building, many factors should be taken into account, which are not always available. One of these factors is the European seasonal energy efficiency ratio (ESEER) defined by the Eurovent Certification Company. It overtakes the outdoor air temperatures from +20° to +35°C with different cooling loads, which is not completely suitable for the Baltic States. Within the research monitoring of cooling system and air parameters was performed during the cooling season. It was indicated that the distribution of the energy generated by the investigated object differs significantly from the distribution of influence factors according to ESEER test methodology. The calculation of the annual energy consumption for the particular historic building according to the recorded power distribution within the outdoor air temperature ranges was performed. Using the proposed method the results are much closer to the actual annual energy consumption of the cooling plant than the one performed using the seasonal efficiency with the base temperature of 18°C.
DOI: 10.1051/matecconf/201824506013
Hipersaite: https://www.matec-conferences.org/articles/matecconf/abs/2018/104/matecconf_eece2018_06013/matecconf_eece2018_06013.html 
Atsauce Brahmanis, A., Borodiņecs, A., Tihana, J., Zemītis, J., Monastyreva, D. Economical Aspects of Water-Mist Assisted Air-Cooled Chillers Usage in the Temperate Climate. MATEC Web Conferences, 2018, Vol.245, 1.-10.lpp. e-ISSN 2261-236X. Pieejams: doi:10.1051/matecconf/201824506013
Papildinformācija Citējamību skaits:
  • Scopus  0
ID 28329